Angle Blade Plate Instrument Set – Complete Angled Blade Plate (ABP) Instrument System
Precision-Engineered U-Profile Seating Chisels, Three-Plane Alignment Guides, Cortical Router Templates, and Articulated Compression Instrumentation for Fixed-Angle Femoral Osteosynthesis.
Designed for hospital trauma centers, hip reconstruction and limb-deformity units, pediatric orthopedic hospitals, and global surgical distributors, our Angle Blade Plate Instrument Set delivers three-dimensional angular accuracy for complex periarticular fractures and corrective osteotomies. Engineered directly by an ISO 13485-certified Angle Blade Plate Instrument Set Manufacturer, this unified Angled Blade Plate (ABP) Instrument System consolidates multi-angle K-wire trajectory aiming, cortical window pre-drilling, U-profile blade tract chiseling, rigid monoblock plate insertion, and active axial compression into a single sterile platform.
- Universal Fixed-Angle Implant Support: Configured as an all-in-one Condylar and Proximal Femoral Blade Plate Instrument Set, supporting 95° Condylar Blade Plates, 130° Proximal Femoral Trauma Blade Plates.
- Bone-Conserving U-Profile Blade Preparation: Unlike large-diameter triple reamers that excavate substantial cancellous bone from the femoral neck, the calibrated U-profile seating chisel compacts trabecular bone around a low-volume track—preserving vascularity and bone stock for revision salvage.
- Three-Plane Rotational & Sagittal Control: Includes a slotted chisel guide with an adjustable sagittal alignment flap and fixed-angle triangular/goniometer wire guides to control coronal, sagittal, and axial blade orientation simultaneously.
- Certified Surgical Metallurgy: Manufactured under ISO 13485:2016 certified quality systems.

Standard Set Configuration – Angle Blade Plate Instrument Set
Below is the standard factory Bill of Materials for the Angle Blade Plate Instrument Set. Optional Pediatric/Adolescent seating chisels (10mm/12mm profile), cannulated blade plate modules, and custom OEM private-label laser markings are available upon request.
- Chisel Guide : 1 Qty
- Condylar Plate Guide : 1 Qty
- Drill Bit Quick Coupling 2 mm x 100 mm : 1 Qty
- Impactor : 1 Qty
- Inserter-Extractor : 1 Qty
- Quadrangular Positioning Plate : 1 Qty
- Seating Chisel : 1 Qty
- Slotted Hammer : 1 Qty
- Spanner 11 mm : 1 Qty
- Triangular Positioning Plate 100 Degree / 60 Degree / 20 Degree : 1 Qty
- Triangular Positioning Plate 80 Degree / 70 Degree / 30 Degree : 1 Qty
- Triangular Positioning Plate 90 Degree / 50 Degree / 40 Degree : 1 Qty
- Triple Drill Guide 130 Degree : 1 Qty
- Graphics Aluminium Box with Silicone Fittings : 1 Qty


Monoblock Fixed-Angle Biomechanics: The Unified Angled Blade Plate (ABP) Instrument System
While sliding hip screws and cephalomedullary nails address routine extracapsular fractures, complex reconstructive procedures—such as Pauwels valgus intertrochanteric osteotomies for femoral neck nonunions, proximal femoral varus/derotational osteotomies, and comminuted distal femoral condylar fractures—frequently require a rigid, one-piece monoblock fixed-angle construct. Because an angled blade plate features no moving barrel-screw junction, it resists torsional rotation and varus bending moments while occupying minimal volume inside the femoral neck or condylar block.
However, because the blade and shaft are forged as a single fixed-angle implant, surgical precision during bone channel preparation is critical: the seating chisel must enter at the exact coronal angle, sagittal slope, and rotational version required for the plate shaft to sit flush against the femoral diaphysis. Recognized across hospital value analysis committees and international public health tenders as a premier Angled Blade Plate (ABP) Instrument System, our Angle Blade Plate Instrument Set provides the mechanical reference guides, cortical routers, and insertion holders necessary to make three-plane blade seating predictable and repeatable.
Reconstructive & Trauma Indications: Turnkey Femoral Osteotomy, Nonunion, and Condylar Fracture Fixation Set
By housing proximal 130° trauma guides and 95° condylar guides inside one modular container, trauma centers and reconstructive orthopedic units can address both acute periarticular fractures and complex revision salvage. Operating as an all-in-one Femoral Osteotomy, Nonunion, and Condylar Fracture Fixation Set, the system supports:
Proximal Femoral Salvage, Corrective Osteotomies & Distal Condylar Applications
Femoral Neck & Pertrochanteric Nonunion Salvage: Valgus intertrochanteric osteotomy (Pauwels repositioning osteotomy) to convert vertical shear forces into physiological axial compression in ununited femoral neck fractures and failed cephalomedullary nail/DHS revisions.
Corrective Proximal & Distal Femoral Osteotomies: Intertrochanteric and subtrochanteric varus, valgus, flexion, extension, and rotational osteotomies for developmental hip dysplasia (DDH), coxa vara/valga, Perthes disease sequelae, and post-traumatic femoral malunions managed with our Femoral Osteotomy, Nonunion, and Condylar Fracture Fixation Set.
Distal Femoral Supracondylar & Intercondylar Fractures (AO/OTA 33-A & 33-C): Fixed-angle 95° Condylar Blade Plate osteosynthesis for extra-articular supracondylar and reconstructed articular intercondylar fractures of the distal femur, as well as distal femoral nonunions.
Unstable Subtrochanteric & Proximal Femoral Fractures (AO/OTA 31-A3 & 32): Direct open reduction and fixed-angle blade-plate neutralization of complex subtrochanteric fractures where medullary canal obliteration or narrow canal anatomy contraindicates intramedullary nailing.
Sterile Processing (SPD) Efficiency & Modular Graphic Case Architecture
Hospital Sterile Processing Departments (SPD) and operating room managers evaluate heavy reconstructive trauma trays on autoclave moisture drainage, impact-tool organization, and ergonomic container weight limits. Our Angle Blade Plate Instrument Set is housed in a perforated, hard-anodized aluminum sterilization container paired silicone holders.
- High-Flow Steam Perforation Geometry: Housed in a two-tier hard-anodized aluminum sterilization container with a perforation ratio greater than 45% to ensure rapid steam penetration during standard pre-vacuum autoclave cycles (132°C / 270°F for 4 minutes).
- Ergonomic Modular Split-Tray Design: Chisel, Chisel, Inserter-Extractor, Chisel, Hammer and Triangular Positioning Plate are distributed in Bipolar Instrument Set across balanced, stackable modular tiers so the loaded sterilization case remains strictly below the 25 lb (11.3 kg) AAMI ST77 limit.
Direct OEM & Global Supply: Certified Angle Blade Plate Instrument Set Manufacturer
Sourcing fixed-angle reconstructive instrumentation directly from a dedicated Angle Blade Plate Instrument Set Manufacturer eliminates third-party distributor markups and guarantees exact geometric matching between the U-profile seating chisel and your angled blade plate implants. If a seating chisel is machined even 0.3mm too wide, the blade plate loses press-fit rotational stability in osteoporotic cancellous bone; if machined too narrow, impaction can fracture the femoral neck or condyles. Every seating chisel, router template, and plate holder is verified on measuring machines against master implant gauges prior to shipment.
- Impact-Resistant Chisel & Router Metallurgy: U-profile seating chisels, cortical routers, and drill bits are forged and vacuum heat-treated to 50–54 HRC to withstand heavy mallet impaction without edge deformation.
- Custom OEM Blade-to-Chisel Calibration: As a full-service Angle Blade Plate Instrument Set Manufacturer, we calibrate seating chisels and plate holders to match standard AO 95°/130° U-profile geometry or your proprietary cannulated/solid blade plate blueprint.
- Global Regulatory: Manufactured in an ISO 13485:2016 certified facility.
Frequently Asked Questions
Q1: Is there any difference between an Angle Blade Plate Instrument Set and an Angled Blade Plate (ABP) Instrument System?
In orthopedic surgery and global B2B procurement, Angle Blade Plate Instrument Set and Angled Blade Plate (ABP) Instrument System refer to the exact same fixed-angle surgical platform. Our unified system fulfills both international distributor catalog specifications and clinical AO hospital tender requirements.
Q2: Does this Condylar and Proximal Femoral Blade Plate Instrument Set support both 95° and 130° blade plates?
Yes. Engineered as a complete Condylar and Proximal Femoral Blade Plate Instrument Set, the tray includes the fixed-angle wire guides , adjustable goniometer guide, U-profile seating chisels, and universal collet plate holder required to insert 95° Condylar Blade Plates and 130° Proximal Femoral Trauma Blade Plates.
Q3: Why is a three-hole cortical drill template included in this Femoral Osteotomy, Nonunion, and Condylar Fracture Fixation Set?
Driving a 16mm-wide U-profile seating chisel directly into the dense lateral cortex of the femur can cause longitudinal cortical splitting. In our Femoral Osteotomy, Nonunion, and Condylar Fracture Fixation Set, the hardened three-hole cortical drill template guides three adjacent Ø 4.5mm drill holes across the entry window, which are then connected using the side-cutting router bit—allowing the seating chisel to enter smoothly without cortical hoop stress.
Q4: What are the sterilization parameters for the Bipolar Instrument Set container?
The anodized aluminum sterilization container is validated for standard hospital pre-vacuum steam autoclave sterilization at (132°C / 270°F) for 4 minutes with a minimum 20–30 minute drying cycle, as well as 134°C (273°F) for 3 minutes under European/WHO sterilization protocols.
Q5: As an Angle Blade Plate Instrument Set Manufacturer, do you offer pediatric/adolescent osteotomy chisel sizes and OEM branding?
Yes. As a direct Angle Blade Plate Instrument Set Manufacturer, we provide comprehensive OEM and private-label services, including custom laser-etched brand logos, bespoke anodized case colors, and dedicated infant/child/adolescent U-profile seating chisels (8mm, 10mm, and 12mm blade widths) matched to your pediatric hip osteotomy implant line.