PFN Nail Instrument Set – Complete Proximal Femoral Nail (PFN) Instrument System
Precision-Engineered Dual-Screw Cephalomedullary Targeting, Trochanteric Canal Preparation, and Active Axial Compression Instrumentation for Proximal Femoral Osteosynthesis.
Designed for hospital trauma centers, orthopedic specialty centers, and global surgical distributors, our PFN Nail Instrument Set delivers rigid rotational control and repeatable fluoroscopic targeting for unstable extracapsular hip fractures. Engineered directly by an ISO 13485-certified PFN Nail Instrument Set Manufacturer, this unified Proximal Femoral Nail (PFN) Instrument System consolidates lateral trochanteric entry, dual-axis femoral neck drilling, and distal static/dynamic interlocking into a single color-coded sterile platform.
- Dual-Screw Anti-Rotation Biomechanics: Configured as a high-precision Cephalomedullary Hip Nail Instrument Set, guiding both a primary load-bearing femoral neck lag screw (Ø 8.0mm) and a superior anti-rotation hip pin (Ø 6.4mm) to eliminate rotational head cut-out (the “Z-effect”).
- Universal Short & Long Nail Support: Operates as an all-in-one Short and Long PFN Interlocking Instrument Set, supporting standard short PFN nails (180mm–240mm) and long anatomic PFN nails (300mm–420mm) across 135° degree neck-shaft angles.
- Turnkey Hip & Proximal Femur Coverage: Purpose-built as a comprehensive Intertrochanteric and Subtrochanteric Fracture Nailing Set for Ø 9.0mm to Ø 12.0mm cannulated nails and Ø 4.9mm distal locking bolts.
- Aiming Arm: Ensures unobstructed anteroposterior (AP) and lateral C-arm fluoroscopy of the femoral head and neck while maintaining zero mechanical deflection.

Standard Set Configuration – PFN Nail Instrument Set
Below is the standard factory Bill of Materials for the PFN Nail Instrument Set. Flexible medullary reamer sets for long nails, custom neck-shaft angle guides (130°, 125°), and OEM private-label laser markings are available upon request.
- Trocar for 8 mm Protection Sleeve : 1 Qty
- Trocar for 6.4 mm Protection Sleeve : 1 Qty
- Guide Wire Sleeve for 2 mm Guide Wire : 1 Qty
- Guide Wire Sleeve for 2.5 mm Guide Wire : 1 Qty
- Drill Sleeve for 4 mm Drill Bit : 1 Qty
- Protection Sleeve for 4 mm Drill Sleeve : 1 Qty
- Protection sleeve for 6.4 mm reamer : 1 Qty
- Protection sleeve for 8 mm reamer : 1 Qty
- Ram Rod : 1 Qty
- Ram : 1 Qty
- Spanner 17 mm : 1 Qty
- PFN Nail Holding Bolt : 1 Qty
- Driving Head : 1 Qty
- PFN Target Device, 135° : 1 Qty
- Tissue Protector : 1 Qty
- Holding Forcep for Guide Wire : 1 Qty
- Bone Awl : 1 Qty
- Hexagonal Screw Driver Cannulated for 8 mm and 6.4 mm Bolts : 1 Qty
- Hexagonal Screw Driver for 4.9 mm Bolts : 1 Qty
- Depth Gauge 110 mm with Long Sleeve : 1 Qty
- Medullary Tube, 450 mm Length : 5 Qty
- Threaded Guide Wire 2.5 mm, 450 mm Long : 1 Qty
- Reamer for 6.4 mm PFN Bolt : 1 Qty
- Reamer for 8 mm PFN Bolt : 1 Qty
- Proximal Cannulated Reamer 15 mm : 1 Qty
- Drill Bit 4 mm, Plain Shank, 250 mm Long : 1 Qty
- Drill Bit 3.5 mm, Plain Shank, 250 mm Long : 1 Qty
- Graphics Aluminium Box with Silicone Fittings : 1 Qty





Dual-Axis Cephalomedullary Biomechanics: The Next-Generation Proximal Femoral Nail (PFN) Instrument System
Unstable pertrochanteric and reverse oblique fractures subject extramedullary side plates to high bending moments, frequently leading to varus collapse, medial shaft displacement, or lag screw cut-out. By positioning the load-bearing axis directly inside the medullary canal, our Proximal Femoral Nail (PFN) Instrument System shortens the biomechanical lever arm across the hip joint and provides immediate lateral buttress support against the greater trochanter.
Recognized by international hospital value analysis committees as a comprehensive Cephalomedullary Hip Nail Instrument Set, our PFN Nail Instrument Set is engineered around a parallel three-part sleeve system (outer soft-tissue sleeve, drill sleeve, and guide-wire sleeve). This allows the surgeon to place two parallel Ø 2.8mm guide wires into the femoral neck simultaneously—securing provisional rotational stability of the femoral head fragment before stepped reaming and lag screw insertion ever begin.
Universal Implant Compatibility: Short and Long PFN Interlocking Instrument Set Engineering
Hospital operating rooms and implant distributors require a versatile targeting platform that handles both geriatric trochanteric fractures and complex ipsilateral shaft extensions without opening multiple auxiliary sets. Configured as a unified Short and Long PFN Interlocking Instrument Set, this system provides precision mechanical indexing across every step of the procedure:
- Aiming Bow: The targeting arm features precision-machined ports for 135° cephalomedullary trajectories, accommodating variations in patient femoral neck-shaft anatomy.
- Calibrated Stepped Reamers with Positive Depth Stops: Includes separate cannulated stepped drills for the inferior load-bearing lag screw and superior Ø 6.4mm anti-rotation hip pin, equipped with mechanical depth stops that lock at the exact millimeter measured on the guide wire to prevent subchondral joint perforation.
- Controlled Interfragmentary Neck Compression: The cannulated lag screw driver incorporates an integrated compression nut, allowing the surgeon to apply controlled axial compression across the intertrochanteric fracture line while keeping the anti-rotation pin trajectory aligned.
- Jig-Guided & Freehand Distal Locking: Provides modular distal targeting ports on the aiming arm for static and dynamic Ø 4.9mm locking of short nails, plus a radiolucent “perfect circle” freehand targeting wand and calibrated Ø 4.0mm long drills for distal locking of long PFN nails.
- Minimally Invasive Trochanteric Entry Protection: Features a 6° valgus-compatible curved entry awl and a stepped Ø 14.0mm–17.0mm proximal entry reamer housed inside a soft-tissue protection sleeve to preserve the gluteus medius insertion.
High-Volume Clinical Indications: Turnkey Intertrochanteric and Subtrochanteric Fracture Nailing Set
Geriatric and high-energy hip fractures demand rapid, blood-sparing surgical intervention to permit early postoperative mobilization. Engineered specifically as an Intertrochanteric and Subtrochanteric Fracture Nailing Set, this platform equips orthopedic trauma surgeons to manage the most biomechanically demanding fractures of the proximal femur.
Pertrochanteric, Reverse Oblique & Ipsilateral Shaft Applications (AO/OTA 31-A1, 31-A2, 31-A3 & 32)
- Unstable Pertrochanteric & Intertrochanteric Fractures (AO/OTA 31-A2): Multi-fragmentary intertrochanteric fractures with posteromedial lesser trochanteric comminution where intramedullary load-sharing prevents varus collapse.
- Reverse Oblique & Transverse Trochanteric Fractures (AO/OTA 31-A3): Fractures involving a compromised lateral femoral cortex where sliding hip screw side plates fail due to uncontrolled medialization of the femoral shaft.
- High & Low Subtrochanteric Fractures: Stabilized using the long-nail configuration of our Intertrochanteric and Subtrochanteric Fracture Nailing Set, resisting powerful flexion, abduction, and external rotation forces acting on the proximal segment.
- Ipsilateral Trochanteric/Shaft & Pathological Fractures: Segmental femoral trauma and prophylactic intramedullary stabilization of metastatic lesions in the intertrochanteric and subtrochanteric zones.
Sterile Processing (SPD) Efficiency & Modular Graphic Case Architecture
Hospital Sterile Processing Departments (SPD) and operating room managers evaluate cephalomedullary nailing systems on autoclave reliability, ergonomic weight distribution, and rapid visual inventory counts. Our PFN Nail Instrument Set is housed in a perforated, hard-anodized aluminum sterilization container paired with silicone holders.
- High-Flow Perforation Geometry: Engineered with open-surface perforation ratio to guarantee rapid steam penetration and moisture evacuation during standard pre-vacuum steam sterilization cycles (132°C / 270°F for 4 minutes).
- Ergonomic Modular Split-Tray Design: PFN Nail Instrument Set Tray engineered to comply with the 25 lb (11.3 kg) AAMI ST77 weight limit per container by distributing heavy reduction forceps and drilling/tapping modules across balanced, stackable graphic tiers.
Direct OEM & Global Supply: Trusted PFN Nail Instrument Set Manufacturer
Sourcing cephalomedullary targeting systems directly from an experienced PFN Nail Instrument Set Manufacturer eliminates third-party distributor markups and guarantees absolute coaxial alignment between your targeting jigs and PFN implants. Every aiming bow and cam-lock targeting block is inspected on measuring machines (CMM) and test-drilled against master nail gauges prior to shipment.
- Surgical Cutting & Drilling Metallurgy: Stepped reamers, awls, taps, and calibrated twist drill bits are machined from stainless steel, vacuum heat-treated to 48–52 HRC for enduring flute sharpness.
- Custom OEM Jig-to-Implant Calibration: As a full-service PFN Nail Instrument Set Manufacturer, we calibrate proximal dual-screw aiming blocks to match standard AO PFN geometry or your proprietary short/long nail blueprint.
- Global Regulatory & Tender Compliance: Manufactured in an ISO 13485:2016 certified facility
Frequently Asked Questions
Q1: What is the clinical advantage of this Proximal Femoral Nail (PFN) Instrument System?
Engineered as a dual-screw Cephalomedullary Hip Nail Instrument Set, our Proximal Femoral Nail (PFN) Instrument System guides both a primary load-bearing femoral neck lag screw and a superior Ø 6.4mm anti-rotation hip pin. This parallel two-screw configuration prevents rotational malalignment of the femoral head fragment during insertion and resists postoperative varus cut-out in osteoporotic bone.
Q2: Does a single PFN Nail Instrument Set work for both short and long PFN nails?
Yes. Configured as a combined Short and Long PFN Interlocking Instrument Set, the tray includes the long ball-tip reaming guide wire, radiographic ruler, and freehand distal targeting wand required for Long PFN nails (300mm–420mm), alongside the jig-mounted distal targeting sleeves used for Short PFN nails (180mm–240mm).
Q3: Does the targeting jig support 135° femoral neck-shaft angles?
Absolutely. The aiming arm and cam-lock targeting module in our Intertrochanteric and Subtrochanteric Fracture Nailing Set accommodate 135° proximal nail angles, allowing surgeons to match native patient neck-shaft anatomy.
Q4: What are the sterilization parameters for the PFN Nail Instrument Set container?
The anodized aluminum sterilization case is validated for standard hospital pre-vacuum steam autoclave sterilization at (132°C / 270°F) for 4 minutes with a minimum 20–30 minute drying cycle, as well as 134°C (273°F) for 3 minutes under European/WHO sterilization protocols.
Q5: As a PFN Nail Instrument Set Manufacturer, do you offer OEM private-label branding and custom BOM layouts?
Yes. As a direct PFN Nail Instrument Set Manufacturer, we provide comprehensive OEM and private-label manufacturing for orthopedic implant companies and regional distributors, including custom laser-etched brand logos, bespoke anodized case colors, tailored silicone bracket layouts, and custom targeting jig calibration.
Do you have any questions for PFN Nail Instruments Set?
Please fill this form we will get in touch with you shortly.


